Home
Solutions β–Ό
ODM/OEM ▼
Products Configurator Blog About Contact
POWER QUALITY SOLUTIONS

Clean Power for Every Industry & Grid

Harmonic filtering, reactive power compensation and load balancing β€” from low-voltage modules to medium-voltage STATCOM systems. Explore how each Nengdu solution works, its key specifications and which application it fits.

2nd–50thHarmonic Filtering
<100ΞΌsAPF Response
6–35kVMV STATCOM
40+Countries Served
NDPQC-AHF active harmonic filter cabinet
SOLUTION 01 · HARMONIC FILTERING

Active Harmonic Filter (APF)

A power-electronics device connected in parallel with your load. It measures the harmonic current in real time and injects an equal-but-opposite current to cancel it β€” so the grid only sees clean, sinusoidal current.

  • Filter range: 2nd to 50th harmonics, up to 98% filtering efficiency
  • Response: < 100ΞΌs, fully adaptive to changing loads
  • Topology: 3-level IGBT β€” low loss, high waveform quality
  • Bonus: reactive power compensation & three-phase load balancing
ModelsNDPQC-AHF module / cabinet / wall-mount
Voltage220V / 400V / 440V / 480V / 690V
Rating25A – 600A (parallel up to 3000A+)
Target THDBelow 5% at point of common coupling
NDPQC-SVG static var generator module
SOLUTION 02 · REACTIVE POWER

Static Var Generator (SVG)

An IGBT-based voltage-source inverter that generates or absorbs reactive power instantly, correcting power factor and stabilizing voltage β€” without the switching steps or resonance risk of capacitor banks.

  • Compensation: continuous, stepless from -1.0 to +1.0 power factor
  • Speed: 25.6kHz switching, responds in milliseconds
  • Harmonics: 2nd to 25th mitigation as a bonus
  • Long life: no inrush, no contactor wear, minimal maintenance
ModelsSVG module / Mini SVG 2U / rack & wall mount
Voltage220V / 380V / 400V / 480V / 690V
Rating5kvar – 200kvar per unit, parallel for higher
Target PF0.99+ under normal loading
NDPQC-HPFC hybrid power factor correction cabinet
SOLUTION 03 · COST-EFFECTIVE PFC

Hybrid Power Factor Correction (HPFC)

Combines active SVG modules with capacitor-reactor passive steps. Capacitors handle the coarse reactive demand economically; the SVG polishes the fine remainder β€” the best value for large reactive loads.

  • Economy: cheaper than a pure SVG for the same kvar
  • Precision: automatic TSC + contactor + SVG fine control
  • Power factor: -1.0 to +1.0 continuously adjustable
  • Loss: low power consumption < 2.5%
ModelsHPFC compensation cabinet
Voltage400V / 480V / 690V
Rating50kvar – 600kvar (custom)
TopologyTSC steps + SVG module hybrid
NDPQC-SPC smart power factor correction device
SOLUTION 04 · DISTRIBUTION GRID

Smart Power Factor Correction (SPC)

A three-phase load-imbalance and reactive-power auto-correction device designed for outdoor pole-mount or transformer-mount installation β€” small, light and maintenance-free for distribution grids.

  • Imbalance: auto-balances three-phase loading on site
  • Installation: pole / transformer / distribution room
  • Control: timed or load-factor start-up logic
  • Communication: wireless remote monitoring ready
ModelsSPC smart compensation device
Voltage380V three-phase
Rating30kvar – 150kvar (custom)
MountingOutdoor pole / transformer / cabinet
Nengdu 10kV medium voltage STATCOM system
SOLUTION 05 · MEDIUM VOLTAGE

Medium-Voltage STATCOM

High-voltage dynamic reactive power compensation for utility substations, renewable energy integration and heavy industrial feeders β€” with full protection and grid-code compliance.

  • Speed: response ≤ 10ms, stepless control
  • Voltage: 6kV / 10kV / 35kV classes
  • Power: 1Mvar – 50Mvar per project
  • Form: containerized or indoor cabinet
Models10kV STATCOM / HV SVG cabinet
Voltage6kV / 10kV / 35kV
Rating1Mvar – 50Mvar (project based)
ApplicationSubstation, wind/solar farm, heavy industry
Nengdu DC fast charging station
SOLUTION 06 · NEW ENERGY

EV Charging Solutions

DC fast charging stations for public charging, highway service areas, fleet depots and commercial parking β€” with smart payment integration and remote management.

  • Power: 60kW – 240kW dual-gun DC fast chargers
  • Compatibility: CCS2 / CHAdeMO / GB/T
  • Management: OCPP, card / QR-code start
  • Integration: payment & charging network platforms
ModelsDC fast charging station
Power60kW / 120kW / 240kW
ConnectorsCCS2 / CHAdeMO / GB/T
ProtocolOCPP 1.6 / 2.0
Nengdu low voltage capacitor reactor compensation cabinet
SOLUTION 07 · PASSIVE PFC

Capacitor & Reactor Systems

Detuned capacitor-reactor banks and low-voltage compensation cabinets for stable, low-harmonic environments β€” the classic, reliable way to correct power factor at the lowest cost per kvar.

  • Switching: contactor or thyristor (TSC) options
  • Detuning: 7% / 14% reactors avoid resonance
  • Control: intelligent power factor controller
  • Range: 30kvar – 600kvar per cabinet
ModelsLV compensation cabinet / capacitor reactor cabinet
Voltage400V / 480V / 690V
Rating30kvar – 600kvar (custom)
Accessoriescontroller, detuned reactor, fuses, thyristor switch
Nengdu engineers performing power quality site survey
SOLUTION 08 · SERVICE

Power Quality Audit

On-site measurement, harmonic analysis and system design β€” our engineers study your load profile, measure THD / PF / imbalance and deliver a BOM-ready proposal for the right APF, SVG or HPFC configuration.

  • Measurement: THD, power factor, imbalance, voltage events
  • Analysis: harmonic spectrum & resonance risk review
  • Design: BOM-ready proposal with ratings & layout
  • Cost: free for qualifying projects
Deliverableaudit report + equipment proposal
ScopeLV to MV, single site or multi-site
Coverageglobal β€” remote or on-site
Timelinereport within 5–7 working days

Not Sure Which Solution Fits Your Site?

Send us your single-line diagram, load list or electricity bill β€” our engineers will recommend the right APF / SVG / HPFC configuration and quote within 24 hours. Free of charge.

Chat on WhatsApp